Fenestration Testing Services

Fenestration Testing and Certification for everything from residential vinyl, aluminum, wood and fiberglass windows, commercial curtain walls, roll up doors and garage doors, and window wall systems

Fenestration Testing refers to the process of testing the performance of windows, doors, and other building envelope components such as skylights, curtain walls, and storefronts. The purpose of fenestration testing is to evaluate the ability of these components to resist various environmental factors such as wind, water, and air infiltration, as well as to assess their energy efficiency and acoustic performance. The results of fenestration testing are used to determine whether the components meet the performance requirements specified in building codes and standards, as well as to identify any areas for improvement. This information can then be used by architects, engineers, and building owners to select the most appropriate fenestration components for their projects, and to ensure that these components perform as expected over the long term.

Our Certifications and Accreditations

Intertek’s Certification Marks are proof to architects, building officials and local inspectors that your fenestration product has met local, national or international safety requirements.

We are accredited to ISO 17025 by IAS, FGIA (previously AAMA), Miami-Dade County, The State of Florida, SGCC, IGCC, and NFRC.

ASTM F3561 Forced-Entry-Resistance of Fenestration Systems
View the Webinar

Fenestration Testing Services

  • Accelerated Weather Testing
  • Acoustical Testing: Impact sound absorption, Sound absorption, Transmission loss
  • Applicable Glazing Standards: ASTM E119, ASTM E152, ASTM E163, CAN 4 S104, CAN 4 S106, CAN/ULC S101, NFPA 251, NFPA 252, NFPA 257, UBC 7-1, UBC 7-2, UBC 7-4, UL 9, UL 10B, UL 263
  • Attack Resistance: ASTM 1233, California Department of Corrections, FRA 49 CFR Part 223
  • Bullet Resistance: ANSI Z26.1, ANSI Z97.1, ASTM F1233, FRA 49 CFR Part 223, NIJ0108.1, UL 752
  • Curtain Wall Testing: AAMA 501, ASTM E283, ASTM E331, ASTM E547, ASTM E330, Fire Resistance, ASTM E119, ASTM E152, ASTM E163, NFPA 252, NFPA 257
  • DASMA
  • Full Spandrel Glass Testing
  • Fallout Resistance per PBS: 4-0885
  • Fallout Resistance per Custom Requirements
  • Impact Safety Testing (Tempered, laminated, organic coated and plastic products): ANSI Z97.1, CPSC 16CFR 1201
  • Insulated Glass Testing (Accelerated weathering, fogging, humidity): ASTM E546, ASTM E773, ASTM E774, ASTM E2188, ASTM E2189, ASTM E2190
  • NAFS (North American Fenestration Standard): AAMA 101, WDMA I.S.2, Canadian Standard (CSA A440), ENERGY STAR® for Canada (NRCan), ENERGY STAR® for US (NFRC)
  • Safety Glazing Testing: ANSI Z97.1, CPSC 16 CFR 1201, UBC 24-2, UL 9
  • Motor Vehicle Glazing Testing: ANSI Z26.1
  • Windborne Debris Testing (Hurricane and Tornado)

Comprehensive Fenestration Testing Brochure

 
 

Need help or have a question?

+1 800 967 5352
UK/EIRE:
+44 116 296 1620
S. AMER:
+55 11 2842 0444
APAC:
+86 400 886 9926
Benelux:
+31 88 126 8888
Germany
+49 711 27311 152
UAE
+971 4 317 8777
India
+91 11 4159 5408
 
 
 
 
 
 
33494
171
6951/7521/7527/7541/7605/
50
34359822719
51653,34359830861,34359760725
34359846920,33410,33412,33411