Bulk Composition of Catalysts
Catalyst bulk composition analysis
Intertek tests for the bulk composition of catalysts, analysed in terms of the phases and elements present. A combination of both approaches is advisable for a full description of catalyst bulk composition.
Phase analysis by X-ray diffraction (XRD) goes beyond elemental composition to characterise the crystalline forms present. An active metallic element might be present as pure metal, oxide, mixed oxide, carbonate, carbide, etc. Catalyst support materials can undergo changes under reaction conditions, such as transition aluminas transforming to corundum. Phase identification is based on the International Centre for Diffraction Data PDF database. Quantification of phases can be based on traditional methods with calibration mixtures but our preference is to use standardless methods where possible. If crystal structures are available, as they are for most inorganic phases, the Rietveld method can be used based on these structures.
X-Ray Fluorescence (XRF) examines the bulk composition of catalyst samples, often with minimal sample preparation. XRF provides an overall assessment of the elements present on a new or used catalyst, and estimate concentrations present using a re-iterative semi-quantitative calculation. Intertek identifies catalyst poisoning by elements such as sulphur, chlorine or unwanted heavy metals which may have caused catalyst failure in service.
Support systems may be screened for impurities in a similar way. If there is a requirement to check that actual concentrations present match those in a specification, then quantitative analysis by XRF is appropriate for the accurate determination of major and minor concentrations. XRF is an effective tool for examining catalysts for the elements Na to U in the approximate ranges of 0.01 to 100% with results expressed as elements or oxides (calculated).
For the determination of trace levels of most elements it may be more appropriate to use ICP analysis techniques (OES or MS), for which it is usually necessary to bring the sample into aqueous solution using microwave digestion with acids, or alkaline fusions. The extra sensitivity offered by ICP-OES and particularly ICP-MS more than compensates for the dilution effect of bringing the sample into solution. With these techniques very low concentrations may be observed in one catalyst compared to another e.g. for comparing competitor’s formulations. Similarly it is possible to examine the distribution of heavy metal poisoning throughout a catalyst bed.
Combustion analysers determination carbon, hydrogen, nitrogen, sulphur, halogens and oxygen in suitable matrices. Intertek has several detection methods available depending upon the levels of analytes expected.
Need help or have a question?
Analytical Testing Services
WHITE PAPERS
- Adhesives QA Testing Programs
- Food Contact & Non-Intentionally Added Substances (NIAS)
- The DoC and Regulation 10/2011 for Plastic Food Contact Materials
- Regulation EU 2020/1245 To Amend Regulation EU 10/2011
WEBINARS
- PFAS Monitoring in Environmental and Polymer Samples
- Microplastics and Nanoparticles - Definitions And Regulatory Considerations
- Microplastics and Nanoparticles and Food Contact Applications
CASE STUDIES
- Dissolution of Hydroxyapatite Coatings for Medical Devices
- Particulate Contamination control and analysis
- Polymer Rheology Testing Case Study