ASTM C1505: Standard Test Method for Determination of Breaking Strength and Modulus of Rupture

Standard: ASTM C1505 – Standard Test Method for Determination of Breaking Strength and Modulus of Rupture of Ceramic Tiles and Glass Tiles by Three-Point Loading

Certification Required: N/A

Scope: Per ASTM C1505: "This test method consists of determining the breaking strength and modulus of rupture of ceramic tiles and glass tiles using a three-point loading method."

Applicable Products: Ceramic tiles and glass tiles

Test Procedure: Each specimen is loaded face up onto two support rods. The loading rod is positioned at the midpoint between the two support rods. A load is applied at a constant rate of 145 psi per second until the specimen breaks.

End Result: This test results in the failure load as well as the breaking strength, average breaking strength and modulus of rupture of the specimens.

Special Notes: N/A

Intertek Testing Locations: York, PA

 

 