E-mail Us

Call Us

+1 888 400 0084
+1 281 971 5600

Show other contacts

EMEA UK:+44 161 721 5247Benelux:+31 88 126 8888France:+33 3 85 99 12 80APAC:+65 6322 8228EU (IRE):+353 90 646 0200Germany:+49 711 27311 514Switzerland:+41 61 686 4800Mexico:01 800 5468 3783+52-55-5091-2150Brazil:+55 11 2322 8033Australia:+61 3 9315 1844India:+91 (22) 4245 0204
 
 

Catalyst Poisoning Testing

Poisoned catalyst testing and evaluation.

Intertek catalyst testing experts analyse poisoned catalysts, providing answers for catalyst and process clients across industries. By sampling from different areas of a bed and corresponding analyses, a profile of the extent of catalyst poisoning can be determined. Catalyst poisoning is caused by heavy metals such as mercury, lead and arsenic, possibly originating in feedstocks, having passed through the catalyst bed, causing expensive catallyst poisoning and failure.

XPS and SIMS are sensitive tools for studying catalyst poisoning providing there is little associated fouling. In some cases analytical STEM is able to identify the growth of new structures. Catalyst poison fronts may be determined from cross-sections.

Mercury catalyst poisoning can be determined directly on the catalyst without the need for digestion, by the use of a combustion-atomic absorption analyser. The working range is from ppb to 50 ppm of mercury. The same instruments can be used for the direct examination of mercury in feedstocks.

Lead, arsenic and many other suspect elements including phosphorus can be determined by ICP techniques after bringing the catalyst into solution. Detection limits for ICP-OES are ppb level in solution, whereas for ICP-MS are ppt level in solution for many elements.

The sulphur content of new and used catalysts can be examined after combustion in a stream of oxygen, using infra red detection of the combustion products. At the same time carbon determination is performed on the same instrument. Major to minor levels of sulphur and carbon are determined. Should there be a need to measure trace levels of sulphur then microcoulometric detection on a different instrument can be applied.

Chlorine deposition can be determined by oxidative microcoulometry. whereas water soluble anions can often be leached from catalysts and determined by ion chromatography. Nitrogen contamination can be determined either by a CHN analyser, or for low levels a combustion analyser with chemiluminescence detection.

Catalyst poisoning in some processes routinely progresses to the point of forming a discrete crystalline phase. This is most often seen with sulphur and metal sulphides can be measured by XRD. Appropriate high surface area materials, e.g. oxides, may be used as guard beds to protect a catalyst. Monitoring the relative content of active phase, unconverted phase and of the sulphide gives an indication of catalyst performance and life-expectancy. Intertek MSG provides world-class expertise in catalyst poisoning evaluation and analysis.

to see how Intertek can help your organization with Catalyst Poisoning Testing.