Electrical Fast Transient Generator Calibration

We provide calibration services for Electrical Fast Transient Generators. This calibration provides 50 Ohm and 1,000 Ohm impedance network waveform data that is compared to the requirements listed in IEC 61000-4-4, basic standard.

This table describes our scope of accreditation for electrical fast transient generator calibrations: 

Parameter/Equipment  Range  Best Uncertainty (±)  Comments 
EFT Generators -     IEC 61000-4-4
    50 Ohm Circuit      
       Amplitude (0.250 to 4) kV 4.23%  
       Rise Time 5 μs ± 30 % 4.40%  
       Pulse Width 50 μs ± 30 % 4.40%  
       Burst Period 15ms 3.50%  
    1k Ohm Circuit      
       Amplitude (0.250 to 4) kV 4.29%  
       Rise Time 5 μs ± 30 % 4.35%  
       Pulse Width 50 μs ± 30 % 4.40%  
       Bust Period 15ms 3.58%  

 